LG Refrigerators

Error Code E CH

High-side cycle leakage (sealed system)

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    Verify error using SVC App Step 1 to determine if sealed system or PCB issue. Check evaporator temperature to confirm sealed system problem.

  2. 2

    Check PCB voltage outputs; if PCB voltages are abnormal, replace PCB.

  3. 3

    Measure high and low side pressures and time for equalization after power off. If equalization takes more than 15 minutes, system restriction is confirmed.

  4. 4

    If equalization pressure is above 20 psi, compressor is likely defective (sufficient refrigerant). Replace compressor.

  5. 5

    If equalization pressure is 20 psi or less, refrigerant has leaked. Perform leak test on high pressure side (condenser, drier, compressor discharge pipe) using bubble test or leak detector.

  6. 6

    If high-side leak found, replace the leaking part and drier together.

  7. 7

    If no high-side leak found, inspect low-pressure side parts (evaporator, suction pipe).

  8. 8

    If low-side leak found, replace the leaking part plus compressor and drier (moisture ingress risk on low side).

  9. 9

    If no leak found, install UV drier and inspect at next service visit using UV light and goggles.

  10. 10

    After sealed system repair, error code will disappear automatically when freezer reaches 14°F or below.

This Error Applies To

LG LL31H6530S Series Refrigerators

Service manual exact match: LL31H6530S

Need more help with your LG refrigerators?